Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 119
Filter
1.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 101-107, 2024.
Article in Chinese | WPRIM | ID: wpr-1006354

ABSTRACT

Objective@#The purpose of this study was to investigate the differences in the anti cyclic fatigue performance of Woride KS (WKS), Proteper Gold (PTG), and Hyflex CM (HCM) nickel titanium instruments with different tip diameters in curved root canal models, and to provide reference for the targeted selection of suitable nickel titanium instruments in clinical preparation of curved root canals.

2.
J. res. dent ; 11(2): 25-31, Oct 2023.
Article in English | LILACS-Express | LILACS | ID: biblio-1513036

ABSTRACT

Aims: The aim was to evaluate the cyclic and torsional fatigue resistance among thermally treated NiTi rotary instruments with different design features.Materials and methods: Sixty instruments of three systems were used (n=20): TruNatomy 26.04 (TN 26.04), BassiLogic 25.05 (BL 25.05), and Flat File 25.04 (FF 25.04). The cyclic fatigue test (n=10) was performed to evaluate the time to fracture (s) and the number of cycles until failure (NCF). The torsion test was performed to evaluate the torque (N.cm) and maximum angular deflection until fracture (n=10). The fracture surface of each fragment was examined under a scanning electron microscope. The data were analyzed by Tukey's test (p<0.05).Results: BL 25.05 and FF 25.04 instruments had a higher number of cycles and time to fracture compared with TN 26.04 (p<0.05). TN 26.04 instruments showed lower torque to fracture.Conclusions: Based on the proposed objectives and the methodology used, TruNatomy 26.04 instruments present lower resistance to cyclic fatigue and torsional fatigue when compared to BassiLogic 25.05 and Flat File 25.04 instruments.

3.
J. res. dent ; 11(1): 7-13, May 2023.
Article in English | LILACS-Express | LILACS | ID: biblio-1513029

ABSTRACT

NiTi endodontic instruments for glide path are the most susceptible to fractures inside the root canal, mainly as a result of high torsional stress. Objective: The present study investigated the resistance to torsion and angular deflection of instruments destined for the glide path: ProGlider #16.02; T-File #17.02 and the MK Life #16.02. Materials and methods: Thirty rotating NiTi glide path instruments (n=10) with 25mm lengths were selected. The torsion test was performed based on ISO 3630-01 (1992). Three millimeters from the tip of the instruments, it was attached to a small load cell by a lever arm connected to the torsion shaft. Torsional strength and angular deflection were evaluated. Fracture surfaces were examined by scanning electron microscopy with magnifications of 1000x and 5000x in the cross section, and 50x in the lateral section. Statistical analysis was performed using the Kruskal-Wallis H test, followed by the Down's post hoc test. Results: The ProGlider instrument showed greater torsional strength (p<0.05) compared to the T-File (p<0.05) and MK Life (p<0.05), respectively. However, the T-File showed greater angular deflection (p<0.05) than the other groups tested. Conclusion: It can be concluded that the ProGlider instrument presented greater torque for the fracture, while the T-File instrument presented greater angular deflection.

4.
Braz. dent. j ; 34(1): 12-18, Jan.-Feb. 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1420578

ABSTRACT

Abstract This study aimed to evaluate the influence of temperature on torsional strength and angular deflection of two experimental NiTi rotary instruments manufactured from Blue and Gold thermal treatments and with identical cross-sections. A total of 40 experimental NiTi instruments 25.06 and with a triangular cross-section and manufactured from Blue and Gold thermal treatments were used (n=20). The torsional test was performed in the 3 mm from the tip of the instrument according to ISO 3630-1. The torsional test evaluated the torsional strength and angular deflection to failure at room temperature (21°C ± 1° C) and body temperature (36°C ±1°C). The fractured surface of each fragment was observed by using scanning electron microscopy (SEM). Data were analyzed using an unpaired t test for inter and intra-group comparison and the level of significance was set at 5%. The results showed that the body temperature did not affect the torsional strength and angular deflection of the instruments when compared with room temperature (P>0.05). However, at body temperature, the Blue NiTi instruments presented significantly lower angular deflection in comparison with Gold NiTi instruments (P<0.05). There was no significant difference regarding the torsional strength of the instruments at body temperature (P>0.05). The temperature did not affect the torsional strength of the instruments manufactured from Blue and Gold technology. However, the Blue NiTi instruments presented significantly lower angular deflection than Gold instruments at 36°C temperature.


Resumo O objetivo deste estudo foi avaliar a influência da temperatura nas propriedades de torção (resistência à torção e deflexão angular) de dois instrumentos rotatórios experimentais de NiTi fabricados com secção triangu.ar e tratamentos térmicos Blue e Gold. Quarenta instrumentos experimentais de NiTi 25.06 com tratamento térmico Blue e Gold foram usados (n= 20). Foi avaliada a resistência torcional e a deflexão angular até a fratura na temperatura ambiente (21°C ± 1°C) e corporal (36°C ± 1°C). O teste torcional foi realizado nos 3 mm da ponta dos instrumentos de acordo com a ISO 3630-1. A superfície fraturada de cada instrumento foi observada pelo microscópio eletrônico de varredura (MEV). Os dados foram analisados por meio do teste t não pareado para a comparação inter e intragrupos e o nível de significância à 5%. Os resultados demonstraram que a temperatura corporal não afetou a resistência a torção e deflexão angular quando comparada com a temperatura ambiente (P>0.05). No entanto, na temperatura de 36°C o instrumento com tratamento térmico Blue apresentou menor deflexão angular quando comparado com o Gold (P<0.05). Não houve diferença significante entre os dois instrumentos em relação a resistência à torção. A temperatura corporal não modificou a resistência torcional dos instrumentos fabricados com tecnologia Blue e Gold. No entanto, os instrumentos com NiTi Blue apresentaram menor deflexão angular do que o Gold a 36°C.

5.
Braz. dent. sci ; 26(2): 1-7, 2023. ilus, tab
Article in English | LILACS, BBO | ID: biblio-1436402

ABSTRACT

Objective: The aim of this study was to evaluate the effect of different glide path files on the amount of apically extruded debris. Material and Methods: Sixty single-canaled mandibular premolars were accessed and randomly divided into three groups (n= 20) according to the file used for glid path creation; group A using Traverse file, group B using WaveOne Gold Glider, group C using stainless steel K file. All teeth were then instrumented using the Reciproc system. The debris extruded apically during instrumentation were collected into pre-weighed Eppendorf tubes which were then stored in an incubator at 70 °C for 5 days. The weight of the dry extruded debris was established by subtracting the pre-instrumentation and post instrumentation weights of the Eppendorf tubes. The data were analyzed using one-way ANOVA test, and post hoc analysis. Results: WaveOne Gold Glider produced the least amount of apical extruded debris (0.41±0.25) followed by the Traverse group (0.59±0.20) then the K-file group (0.64±0.16) with a statistically significant difference (p=0.003). Conclusion: Apical extrusion of debris is inevitable during root canal cleaning and shaping. Creation of glide path using engine-driven files produces less amount of apically extruded debris compared to hand-driven K-files. (AU)


Objetivos: O objetivo deste estudo foi avaliar o efeito de diferentes limas glide path na quantidade de detritos extruídos apicalmente. Metodologia: Sessenta pré-molares inferiores com canal único foram acessados e divididos aleatoriamente em três grupos (n= 20) de acordo com a lima utilizada para criação do glid path; grupo A usando lima Traverse, grupo B usando WaveOne Gold Glider, grupo C usando lima K de aço inoxidável. Todos os dentes foram então instrumentados usando o sistema reciprocante. Os detritos extruídos apicalmente durante a instrumentação foram coletados em tubos Eppendorf pré-pesados que foram então armazenados em uma incubadora a 70°C por 5 dias. O peso dos detritos secos extruídos foi estabelecido subtraindo-se os pesos dos tubos Eppendorf antes e após instrumentação. Os dados foram analisados por meio do teste one-way ANOVA e análise post-hoc. Resultados: WaveOne Gold Glider produziu a menor quantidade de detritos apicais extruídos (0,41±0,25) seguido pelo grupo Traverse (0,59±0,20) e depois pelo grupo K-file (0,64±0,16) com uma diferença estatisticamente significativa (p=0,003). Conclusão: A extrusão apical de detritos é inevitável durante a limpeza e modelagem do canal radicular. A criação do glide path usando limas acionadas por motores produz menos quantidade de detritos extruídos apicalmente em comparação com as limas K manuais. (AU)


Subject(s)
Dental Instruments , Dental Pulp Cavity
6.
Rev. Fac. Odontol. Univ. Antioq ; 34(1): 14-30, ene.-jun. 2022. tab, graf
Article in English | LILACS | ID: biblio-1394659

ABSTRACT

Abstract Introduction: Nickel-Titanium (NiTi) endodontic files are made of hyperelastic material with shape memory. However, these files suffer a sudden fracture during the endodontic treatment, which is considered an unfavorable prognosis. Many studies have been conducted to establish fatigue resistance focused on file brands and determine which is better. Although the most common failure mechanisms have been established for motorized endodontic files, the information is scattered, making it difficult to develop clear research trends. Methods: a scoping review was carried out using Scopus, Dimensions.ai, Web of Science, and Science Direct databases to answer screening questions related to the predominant fracture mechanism in NiTi files, test types, and equipment used for experimentation and to identify the most active authors. Results: using the general search terms, 432 research papers were found, of which 75 were finally selected after eliminating duplicates and applying exclusion criteria. Conclusions: typical failure mechanisms for rotatory and reciprocating files were identified based on the panoramic review and bibliometric indicators. Also, the standard mechanical tests for endodontic files and the characteristics of their assemblies were summarized. The most active authors in the area and their nationality were tagged. Finally, gaps for future research are proposed to generate a comprehensive knowledge of NiTi file failure.


Resumen Introducción: las limas de Níquel-Titanio (NiTi) utilizadas en endodoncia están hechas de un material hiperelástico con memoria de forma. Sin embargo, estas limas sufren fractura repentina durante el tratamiento, lo cual se considera un pronóstico desfavorable. Se han realizado diversos estudios para establecer la resistencia a la fatiga de limas, y determinar cuál marca es mejor. Aunque se han establecido los mecanismos de falla más comunes para las limas de endodoncia motorizadas, la información se encuentra dispersa, dificultando la definición de tendencias claras de investigación. Métodos: se realizó una revisión de cobertura temática utilizando las bases de datos Scopus, Dimensions.ai, Web of Science y Science Direct, para responder a preguntas orientadoras relacionadas con el mecanismo de fractura predominante en las limas NiTi, tipos de pruebas y equipos utilizados para la experimentación e identificar los autores más activos en el área. Resultados: utilizando términos generales de búsqueda, se encontraron 435 trabajos de investigación. Finalmente se seleccionaron 75, tras eliminar duplicados y aplicar criterios de exclusión. Conclusiones: a partir de la revisión panorámica de literatura y empleando algunos indicadores bibliométricos, se identificaron los mecanismos de falla más comunes para las limas rotatorias y reciprocantes. Se obtuvo información sobre ensayos mecánicos y los montajes más utilizados para las limas de endodoncia. Se identificaron los autores más activos en el área y su nacionalidad. Por último, se sugieren oportunidades de investigación para generar un conocimiento exhaustivo sobre la falla de las limas NiTi.


Subject(s)
Titanium , Endodontics , Nickel , Review
7.
Article | IMSEAR | ID: sea-216821

ABSTRACT

Context: Cleaning and shaping of the canals damages the root dentin which becomes a gateway to dentinal cracks and thereby causes failure of the treatment. Aim: The aim of this study was to assess and compare dentinal crack formation caused by three different nickel–titanium (NiTi) rotary file systems in primary anterior teeth. Settings and Design: The present in vitro study is an experimental, comparative study. Materials and Methods: One hundred fifty extracted primary anterior teeth were included in this study. The teeth were randomly divided into five groups. Group 1: Pedoflex rotary file system, Group 2: Prime Pedo™ rotary file system, Group 3: Kedo-S2 rotary file system, Group 4: K-files, and Group 5: no instrumentation. Roots were sectioned and viewed under a stereomicroscope for the presence of any cracks. Statistical Analysis Used: The data were analyzed using the Chi-square test and Kruskal–Wallis test. Results: In the coronal, middle, and apical thirds, Group 2 showed a maximum number of crack formations in the middle third (57%), followed by Group 3 (43.3%) and Group 1 (36.7%). Groups 4 and 5 showed no crack formation in all the root sections. The middle third showed a maximum number of crack formations compared to the coronal and apical thirds. Conclusions: Rotary systems render various benefits with an acceptable success in comparison to conventional hand instrumentation. Within the limitation of this study, it was found that Pedoflex rotary file system was the best with the least number of crack formations.

8.
J. res. dent ; 10(2): 1-6, apr.-jun2022.
Article in English | LILACS, BBO | ID: biblio-1395871

ABSTRACT

Background: The aim of this study was to evaluate the cyclic fatigue and torsional fatigue resistance of three thermally treated rotary instruments, such as: Logic 2 25.05 (LOG 25.05), Edge Taper Platinum 25.06 (EDT 25.06) and ProTaper Gold 25.08 (PTG 25.08).Methods: A total of 60 rotary instruments of LOG 25.05, EDT 25.06 and PTG 25.08 were used (n=20). Cyclic fatigue tests were performed at 36°C using an artificial stainless steel canal with a 60ºangle and a 5-mm radius of curvature. The time (in seconds) and number of cycles to fracture (NCF) was recorded. The torsional test evaluated the torque and angle of rotation to failure at 3 mm from the tip according to ISO 3630-1. The fractured surface of each fragment was observed by using scanning electron microscopy (SEM). Data were analyzed using one-way ANOVA and Holm-Sidak's tests for multiple comparison, the level of significance was set at 5%.Results: EDT 25.06 had highest cyclic fatigue resistance (time and NFC), followed by LOG 25.05 and PTG 25.08 (P<0.05). There were no significantly difference between LOG 25.05 and ETP 25.06 regarding the NCF (P>0.05). In relation the torsional test, the LOG 25.05 and ETP 25.06 presented similar torque (P>0.05). The PTG presented greater torque than the other groups (P<0.05). The PTG 25.08 presented the lowest angular rotation to fracture than the other groups (P<0.05). The SEM images demonstrated typical features of cyclic and torsional fracture.Conclusion: In conclusion, the LOG 25.05 and ETP 25.06 presented similar cyclic and torsional properties. The PTG 25.08 showed greater torsional strength.


Subject(s)
Humans , Endodontics
9.
Braz. dent. j ; 32(6): 8-15, Nov.-Dec. 2021. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1355844

ABSTRACT

Abstract The aim of this study was to evaluate surface wear, presence of microcracks and surface irregularities of WaveOne (WO) and WaveOne Gold (WOG) instruments before and after multiple uses. Eight Primary instruments of the WO and WOG systems were evaluated, each one was used to prepare six mesial canals of extracted human mandibular molars. The surface of the instruments was evaluated before use (T0), after instrumentation of three (T1) and six (T2) root canals. Surface wear was analyzed using a three-dimensional optical profiler and the presence of microcracks and surface irregularities were evaluated using a tabletop scanning electron microscopy. The Friedman test was used to assess surface wear and Kruskal-Wallis test to evaluate the presence of microcracks and surface irregularities, with a 5% significance level. There was a significant increase in wear in both groups at T2, compared to T0 (p=0.0003). The surface wear after instrumentation of six canals (T2-T0) was statistically greater in the WOG group, than in the WO group (p=0.02), where the presence of microcracks was significantly greater and increased after multiple uses (p<0.05). The presence of surface irregularities in the cutting blade before and after use was statistically greater in the WOG group than WO group (p<0.05). Wear of the cutting blade, microcracks and surface irregularities were observed on the surface topography of all the instruments after multiple uses. These surface changes may affect the cutting efficiency of WOG files and increase the risk of fracture of WO files.


Resumo O objetivo deste estudo foi avaliar o desgaste de superfície, a presença de microtrincas e irregularidades superficiais dos instrumentos WaveOne (WO) e WaveOne Gold (WOG) antes e após múltiplos usos. Oito instrumentos Primary dos sistemas WO e WOG foram avaliados, cada um utilizado no preparo de seis canais mesiais de molares inferiores humanos extraídos. A superfície dos instrumentos foi avaliada antes do uso (T0), após a instrumentação de três (T1) e seis (T2) canais radiculares. O desgaste de superfície foi analisado utilizando um perfilômetro ótico tridimensional e a presença de microtrincas e irregularidades superficiais foram avaliadas usando um microscópio eletrônico de varredura de bancada. O teste de Friedman foi usado para avaliar o desgaste de superfície e o teste de Kruskal-Wallis para avaliar a presença de microtrincas e irregularidades superficiais, com nível de significância de 5%. Houve um aumento significativo no desgaste em ambos os grupos em T2, comparado a T0 (p=0.0003). O desgaste de superfície após a instrumentação de seis canais (T2-T0) foi estatisticamente maior no grupo WOG que no grupo WO (p=0.02), onde a presença de microtrincas foi estatisticamente maior e aumentou após os múltiplos usos (p<0.05). A presença de irregularidades na superfície da lamina de corte antes e após o uso aumento significativamente no grupo WOG comparado ao grupo WO (p<0.05). Desgaste da lâmina de corte, microtrincas e irregularidades superficiais foram observadas na topografia de superfície de todos os instrumentos após os múltiplos usos. Essas alterações na superfície podem afetar a eficiência de corte dos instrumentos WOG e amentar o risco de fratura dos instrumentos WO.

10.
Natal; s.n; 2021. 59 p. tab, ilus.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1537222

ABSTRACT

Os instrumentos endodônticos de níquel-titânio acionados a motor foram desenvolvidos para se obter um preparo químico-mecânico mais rápido e seguro, no entanto, esses instrumentos apresentam como desvantagem o risco de fraturar durante o seu uso. Diante disso, os fabricantes têm desenvolvido mudanças no design dos instrumentos, nos acabamentos das ligas e na cinemática de uso, pois são características que contribuem para que as fraturas aconteçam. O objetivo deste estudo foi avaliar e comparar propriedades mecânicas de novos instrumentos de níquel-titânio com memória controlada lançados no mercado. Os sistemas WaveOne Gold (WOG; Dentsply Sirona, Ballaigues, Switzerland), WA1 File (WA1; TDKaFile, Cidade do México, México) e X1 File (X1; MK Life, Porto Alegre, RS, Brasil) foram submetidos ao teste de resistência à torção, de acordo com a norma ISO 3630-1, ao teste rigidez à flexão, através do ensaio de flexão em cantiléver (45º) e ao teste de resistência à flambagem. Os resultados foram avaliados através da análise de variância (ANOVA), o teste F e o teste de Tukey, considerando um nível de significância de 5%. No teste de resistência à torção os instrumentos WOG apresentaram maior deflexão angular, ou seja, maior resistência à fratura em torção, enquanto os instrumentos WA1 a menor e na comparação do torque máximo em torção não houve diferença estatística significante entre os sistemas. Nos testes de rigidez a flexão e resistência à flambagem houve diferença estatística significante entre os 3 sistemas, sendo os instrumentos X1 os mais rígidos. No primeiro teste os instrumentos WA1 se apresentaram como os mais flexíveis e no segundo, os instrumentos WOG. Conclui-se que os instrumentos WOG, WA1 e X1 mostraram diferenças estatísticas nos testes mecânicos, sendo os instrumentos WOG e WA1 os mais resistentes à fratura por torção e os mais flexíveis, diferentemente dos instrumentos X1 que se apresentaram mais susceptíveis à fratura por torção e menos flexíveis (AU)


Reciprocating nickel-titanium endodontic instruments have been developed to obtain a faster and safer preparation, however, these instruments have the disadvantage of fracturing during use. Facing this disadvantage, manufacturers have developed changes in instrument design and alloy finishes, as metallurgical characteristics are one of the factors that contribute to fractures. The aim of this study was to evaluate and compare mechanical properties of new nickel-titanium instruments with controlled memory. The WaveOne Gold (WOG; Dentsply Sirona, Ballaigues, Switzerland), WA1 File (WA1; TDKaFile, Mexico City, Mexico) and X1 File (X1; MK Life, Porto Alegre, RS, Brazil) systems were subjected to the torsional fatigue test, according to the ISO 3630-1 standard, flexural stiffness test, through the cantilever flexion test (45°) and buckling resistance test. The results were evaluated through analysis of variance (ANOVA), the F test and the Tukey test, considering a significance level of 5%. In the torsional fatigue test, the WOG instruments showed greater angular deflection, that is, greater resistance to torsional fracture and the WA1 instruments the lesser, and when comparing the maximum torsional torque, there was no statistically significant difference between the systems. In the flexural stiffness and buckling resistance tests, there was a statistically significant difference between the 3 systems, with the X1 instruments being the most rigid. In the first test, the WA1 instruments were the most flexible followed by the WOG instruments. In conclusion, the WOG, WA1 and X1 instruments showed differences in the mechanical tests, with the WOG and WA1 instruments being the most resistant to torsion fracture and the most flexible, unlike the X1 instruments that were more susceptible to torsion fracture and also the most rigid (AU).


Subject(s)
Dental Instruments , Flexural Strength , Mechanical Tests , Analysis of Variance , Volume Electron Microscopy
11.
Braz. dent. j ; 31(6): 605-610, Nov.-Dec. 2020. tab, graf
Article in English | LILACS, BBO | ID: biblio-1132347

ABSTRACT

Abstract This study evaluated the efficiency of using a single instrument from three different rotary multi-file systems and compared them with that of a reciprocating single-file for endodontic retreatment by means of micro-CT. Sixty extracted canines were prepared using a size F2 ProTaper Universal file and obturated. After 30 days of storage at 37ºC and 100% humidity, the teeth were randomly divided into four groups (n=15) based on the type of instrument used to retreatment: ProTaper Next (PTN), ProTaper Gold (PTG), TRUShape 3D (TS), and WaveOne (WO). The canals were retreated using only the size 40 instrument from each system according to the manufacturer's recommendations for torque and speed. The time required to remove the filling material was recorded in seconds. The amount of initial and residual filling material and the quantity of dentin removed were assessed by means of micro-CT. Data were statistically analyzed (ANOVA and Kruskal-Wallis) at a 5% significance level. TS instruments required the highest (p<0.05) amount of time (mean, 384.80 ±144.92) compared with the WO (229.67±68.16) and PTG (248.67±64.22) and not so different from PTN instruments (327.67±133.3). No differences in the amount of dentin removed, initial and residual filling volume, and percentages of filling material were observed among the groups. The use of a single rotary instrument from the PTG, TS, and PTN systems was as effective as that of the single-file reciprocating WO system. However, none of the instruments was able to remove the filling materials completely.


Resumo Este estudo laboratorial avaliou por meio de micro-CT a eficiência do uso de um único instrumento de três sistemas rotatórios em retratamentos endodônticos, comparados a um instrumento único reciprocante. Sessenta caninos extraídos foram preparados usando o sistema ProTaper Universal (F2) e obturados. Após 30 dias de armazenamento a 37 ºC e 100% de umidade, os dentes foram divididos aleatoriamente em quatro grupos (n = 15), de acordo com o instrumento utilizado para remover as obturações endodônticas: ProTaper NEXT (PTN), ProTaper Gold (PTG), TRUShape 3D (TS) e WaveOne (WO). Os canais foram retratados usando apenas o instrumento tamanho 40 de cada sistema, seguindo as recomendações do fabricante para torque e velocidade. O tempo necessário para remover a obturação foi registrado em segundos. A quantidade de material remanescente e o volume de dentina removida foram avaliadas por meio de micro-CT. Análise estatística foi realizada (ANOVA e Kruskal-Wallis), com nível de significância de 5%. O tempo de trabalho no grupo TS foi significativamente maior (p<0.05) (média, 384,80 ± 144,92) comparado a WO (229,67 ± 68,16) e PTG (248,67 ± 64,22), e similar a PTN (327,67 ± 133,3). Não houve diferenças entre os grupos na quantidade de dentina removida e nas porcentagens de material obturador residual. O uso de apenas um instrumento rotatório dos sistemas PTG, TS e PTN foi tão eficaz quanto o do sistema WO reciprocante na remoção do material obturador. No entanto, nenhum dos instrumentos conseguiu remover completamente os materiais obturadores.


Subject(s)
Root Canal Filling Materials , Root Canal Obturation , Titanium , Root Canal Preparation , Retreatment , Dental Pulp Cavity , Equipment Design , X-Ray Microtomography , Nickel
12.
Odontoestomatol ; 22(35): 12-19, jul. 2020.
Article in Spanish | LILACS | ID: biblio-1102987

ABSTRACT

Objetivo: Determinar si existen diferencias en el tamaño de los arcos de NiTi en los calibres 0.012, 0.014 y 0.016 de tres marcas comerciales. Material y métodos: Se utilizaron 180 arcos de NiTi de las marcas American Orthodontics, TD Orthodontics y OrthoPremium. La estadística descriptiva, la ANOVA y el Post Hoc se realizaron en el programa SPSS 18. Resultados: los arcos de American Orthodontics presentaron diferencias estadísticas significativas en la parte anterior y posterior. En los arcos superiores de TD Orthodontics se encontró contracción en el calibre 0.016. En los arcos superiores OrthoPremium presento una contracción en la parte anterior y en el arco inferior de los 10 a los 40mm. Al comparar las tres marcas se encontraron diferencias estadísticas significativas (p<0.05) entre ellas con las pruebas de ANOVA. Conclusiones: existen diferencias en los tamaños de los arcos superiores e inferiores de cada marca y entre ellas.


Objective: To determine if there are differences between the 0.012, 0.014 and 0.016 NiTi archwires of three brands. Material and methods: 180 NiTi archwires of the following brands were used: American Orthodontics, TD Orthodontics and OrthoPremium. Descriptive statistics, ANOVA and Post Hoc were performed in the SPSS 18 program. Results: The American Orthodontics archwires presented significant statistical differences in the anterior and posterior parts. In the TD Orthodontics upper archwires, contraction was found in the 0.016 caliber. In the upper archwires, OrthoPremium presented a contraction in the anterior part and in the lower archwire of 10 to 40mm. When comparing the three brands, significant statistical differences (p <0.05) were found between them with the ANOVA tests. Conclusions: there are differences in the sizes of the upper and lower archwires of each brand and between them.


Objetivo: determinar se existem diferenças no tamanho dos arcos de NiTi em calibres 0, 12, 0, 14 e 0, 16 de três marcas comerciais. Material e métodos: foram utilizados 180 arcos NiTi das marcas American Orthodontics, TD Orthodontics e OrthoPremium. Estatística descritiva, ANOVA e Post Hoc foram realizadas no programa SPSS 18. Resultados: os arcos da American Orthodontics apresentaram diferenças estatísticas significativas na parte anterior e posterior. Nos arcos superiores da TD Ortodontia foi encontrada contração no calibre 0, 16. Nos arcos superiores, o OrthoPremium apresentou contração na parte anterior e no arco inferior de 10 a 40mm. Ao comparar as três marcas, foram encontradas diferenças estatísticas significativas (p <0,05) entre elas com os testes ANOVA. Conclusões: existem diferenças nos tamanhos dos arcos superior e inferior de cada marca e entre eles.


Subject(s)
Humans , Orthodontic Wires , Tooth Movement Techniques , Orthodontics
13.
Chinese Journal of Tissue Engineering Research ; (53): 1566-1570, 2020.
Article in Chinese | WPRIM | ID: wpr-847731

ABSTRACT

BACKGROUND: The preparation and cleaning of severely curved root canal is the difficult point of root canal treatment. A large number of smear layer will be produced in the process of root canal preparation. Removing effectively these debris and smear layer will be conducive to improving the success rate and longterm effect of severely curved root canal treatment. OBJECTIVE: To explore the cleaning efficacy of Twisted File and ProTaper file combined with chemical preparation on smear layer of severely curved root canal by scanning electron microscope. METHODS: Twenty clinically extracted mandibular molars with severely curved root canals were collected and randomly divided into two groups: Twisted File group and ProTaper group. The root canals were prepared by Twisted file and ProTaper Ni-Ti file, respectively. They were prepared by chemical method with 3% NaClO and 17% EDTA. After preparation, the root canals were split longitudinally and the cleaning efficacy of smear layer of coronal, middle and apical thirds was observed by scanning electron microscope. RESULTS AND CONCLUSION: (1) The images of scanning electron microscope showed that the dentinal tubules of root canal coronal thirds in the ProTaper group and Twisted file group were completely open, almost without smear layer. Dentinal tubules of middle thirds were also open, and simply part of them were covered by smear layer. However, dentinal tubules of apical thirds had few and no obvious opening, and was covered by a large number of smear layer. (2) In Twisted file group, the scores of smear layer at root canal apical thirds were higher than coronal and middle thirds (P 0.05). (3) The results showed that the chemo-mechanical preparation with Twisted File and ProTaper could remove effectively the debris and smear layer in the root canal walls of coronal and middle thirds of the severely curved crown, but the removal effect on apical thirds and dentin tubules was not good.

14.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 494-498, 2020.
Article in Chinese | WPRIM | ID: wpr-823069

ABSTRACT

Objective@# Comparision of the central location ability and clearance rate of ProTaper retreatment, Fengdu O-file and M3-RT three kinds of nickel-titanium instruments and hand stainless instruments K-file, H-file. Observe the form of the root canal wall. To provide experimental basis and reference for the clinical application of nickel-titanium instruments for root canal retreatment.@*Methods @#40 simulated resin blocks with the same specification were randomly divided into four groups (n=10). Each group was separately prepared with hand stainless instruments K-file and H-file (group A1), ProTaper retreatment (group B1), Fengdu O-file (group C1), and M3-RT (group D1). Using scanner to obtain the pre- and post-operative images and overlapping the images through Photoshop. Measuring the root canal inner and outer wall resin removal with Image J, compared the central location ability of the four group. A total of 60 mandibular single canal premolars extracted due to orthodontics were collected. The teeth were randomly divided into four groups (n=15) after filling the root canal. Use hand stainless instruments K-file,H-file(group A2), ProTaper retreatment (group B2), Fengdu O-file(group C2) , M3-RT(group D2) to remove the filling materials. The roots were longitudinally sectioned, and the image of the root surface was photographed under the 10 × magnification microscope. The software was used to trace the area of the root canal wall and residual root filling, and the root filling clearance rate of each group was calculated. Two teeth were randomly selected in each group and observed under scanning electron microscope.@*Results@#Within 9 mm from the root tip hole, the central location ability of group B1, C1, D1 was better than that of group A1(P < 0.05). At 4 mm from the root tip hole, group D1 has the best central location ability(P < 0.05). There was no difference of the four instruments at a distance of 10 mm from the root tip hole(P > 0.05). There were various degree of filling material remained in the root canal after the four groups of instruments for retreatment canal preparation. There was no significant difference between group B2, C2, D2(P > 0.05), and both were higher than group A2(P < 0.05). Scanning electron microscope observation results shown that the root canal wall prepared by group B2, C2, D2 was more smooth and continuous than group A2, and the residual filling material was less. @*Conclusion @#The central location ability of three kinds of nickel-titanium root canal retreatment instruments were significantly better than that of hand stainless instruments. ProTaper retreatment, Fengdu O-file and M3-RT three kinds of nickel-titanium root canal retreatment instruments showed good performance, the central location ability of M3-RT was slightly better. Nickel-titanium root canal retreatment instruments are more efficient than traditional hand stainless instruments in removing root fillings and the root canal wall after preparation is smoother and has good continuity.

15.
Journal of Shanghai Jiaotong University(Medical Science) ; (12): 89-92, 2020.
Article in Chinese | WPRIM | ID: wpr-843268

ABSTRACT

Objective:To evaluate the clinical application effect of two nickel-titanium engine driven systems on moderate curved root canals. Methods:Ninety mesial root canals with moderate curvature of extracted human first mandibular permanent molar were randomly divided into three groups: M3 PRO Group, MTwo group and K group. The glide path was firstly prepared by using #10/04 file in M3 PRO group and MTwo group and #10 file in K group respectively.Then the preparation of root canals up to #25 was performed according to the instruction manual in each different group using standardized technique. All data including time required in glide path preparation, shaping preparation, total root canals preparation and changes of working length in root canal were recorded and analyzed statistically by using Analysis of Variance (ANOVA) and LSD-t tests (P<0.05). Results:Root canal glide path preparation time: MTwo group showed significantly less preparation time while M3 PRO group exhibited significantly the longest preparation time. There was significant difference between MTwo group and M3 PRO group (P=0.001). Root canal shaping preparation time: M3 PRO group showed significantly less preparation time while K group exhibited significantly the longest preparation time. Both MTwo group and M3 PRO group showed significantly less preparation time than K group (P=0.004, P=0.001), but there was no significant difference between MTwo group and M3 PRO group (P=0.573). Total root canal preparation time: MTwo group showed the shortest time while K group exhibited the longest time. There were significant differences between MTwo group, M3 PRO group and K group (P=0.004, P=0.033), but no significant difference between MTwo group and M3 PRO group (P=0.451). Changes of root canal working length: There were significant differences among the three groups (P=0.037, P=0.037, P=0.000). M3 PRO group showed a minimal change while K group exhibited significant changes. Conclusion:MTwo nickel-titanium engine driven system with #10/04 file preform a high efficiency in glide path preparation, whilst M3 PRO nickel-titanium engine driven system show less changes in working length. Under the circumstances where the total time required for root canal preparation is not significant, M3 PRO nickel-titanium engine driven system is more suitable for root canal preparation in moderate curved root canals.

16.
Article | IMSEAR | ID: sea-203485

ABSTRACT

Conventional endodontic instruments make the intracanalprocedures versatile with more efficiency and minimumcomplication. The development of microfractures in the I-RaCeNickel-Titanium rotary (NTR) file and ProFile NTR file wasevaluated by using Scanning electron microscopy (SEM).Thirty six maxillary buccal roots and thirty six mandibularmesial roots with an average canal curvature of 37° wereassigned to each group and prepared with 21mm, 0.04 taperNTR files as follows: (1) I-RaCe (2) ProFile. File sizes 0.06 to0.04 were used in a crown-down technique to a master apicalfile (MAF) size of 0.04/25. The MAF instruments wereevaluated by SEM before use, after completion of 7 canals,and after completion of 14 canals. All I-RaCe instrumentsdeveloped microfrcatures by the seven canal evaluation. TheProFile instruments showed no microfrctures at the 7-or-14canal evaluations. I-RaCe files separated at a higher rate thanProFile instruments. Under the conditions of this study, uniquefile design and electropolishing did not inhibit the developmentof microfractures in I-RaCe NTR.

17.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 95-99, 2019.
Article in Chinese | WPRIM | ID: wpr-751038

ABSTRACT

Objective @#To compare the shaping ability of 3 different nickel (Ni)-titanium (Ti) systems in simulated root canals in resin and to provide a reference for clinicians.@*Methods@#Forty-eight resin blocks were prepared using the F360 (Komet, Brasseler GmbH & Co., Lemgo, Germany) (Group 1), F6 SkyTaper (20/06) (Komet, Brasseler GmbH & Co., Lemgo, Germany) (Group 2), F6 SkyTaper (25/06) (Komet, Brasseler GmbH & Co., Lemgo, Germany) (Group 3) and Reciproc R25 systems (VDW, Munich, Germany) (Group 4) (n=12 canals/group). The images taken before and after preparation were superimposed and analyzed by Adobe Photoshop v7.0. The amount of resin removed by each system was measured, and the centering ability was assessed. The data were statistically analyzed using SPSS 20.0.@*Results @#At the 1 mm point, the transportation in Group 4 [(0.10 ± 0.03) mm] was significantly greater than that in Groups 2 [(0.05 ± 0.03) mm] and 3 [(0.05 ± 0.03) mm] (P < 0.05). At the 8 mm and 9 mm points, the transportation values in Group 4 [(0.12 ± 0.06) mm and (0.13 ± 0.05) mm] were significantly higher than those in Groups 2 [(0.05 ± 0.05) mm and (0.05 ± 0.05) mm] and 3 [(0.05 ± 0.04) mm and (0.06 ± 0.05) mm] (P < 0.05). At the 10 mm point, the transportation was significantly greater in Group 4 [(0.13 ± 0.06) mm] than in Group 2 [(0.06 ± 0.06) mm].@*Conclusion@#F6 SkyTaper exhibits better centering ability than Reciproc.

18.
Journal of Prevention and Treatment for Stomatological Diseases ; (12): 167-171, 2019.
Article in Chinese | WPRIM | ID: wpr-750987

ABSTRACT

Objective @#To compare the removal efficiency and the amounts of apically extruded debris using Twisted File (TF), Twisted File Adaptive (TFA), ProTaper, and ProTaper Next combined with ultrasonic irrigation and to provide an experimental basis for the selection of root canal instrumentation in the clinic.@*Methods@#Forty mandibular premolars were randomly divided into 4 groups (n=10 teeth per group). The canals were cut using a Twisted File, Twisted File Adaptive, ProTaper, or ProTaper Next nickel-titanium instrument. The canals were irrigated with ultrasonic irrigation. The apically extruded debris were collected in preweighted Eppendorf tubes. The amount of dental tissue removed and extruded debris were assessed with an electronic balance.@*Results @#The amount of tooth tissue removed in groups A, B, C and D was 20.5 ± 2.0 mg, 17.8 ± 4.2 mg, 20.8 ± 3.9 mg and 16.5 ± 2.2 mg, respectively. Combined with ultrasonic irrigation, the Twisted File and ProTaper had a better removal efficiency than the ProTaper Next(P < 0.05). There was no significant difference in the amount of extruded debris (χ2=4.057, P=0.255) among four groups.@*Conclusion@#The Twisted File and ProTaper had a better removal efficiency than the ProTaper Next combined with ultrasonic irrigation. There was no significant difference in the amount of extruded debris using four Nickel-titanium instruments combined with ultrasonic irrigation.

19.
Restorative Dentistry & Endodontics ; : e19-2019.
Article in English | WPRIM | ID: wpr-741994

ABSTRACT

OBJECTIVES: The purpose of this study was to evaluate the cyclic fatigue, bending resistance, and surface roughness of EdgeEvolve (EdgeEndo) and ProTaper Gold (Dentsply Tulsa Dental Specialties) nickel-titanium (NiTi) rotary files. MATERIALS AND METHODS: The instruments (n = 15/each) were tested for cyclic fatigue in single- (60° curvature, 5-mm radius) and double-curved (coronal curvature 60°, 5-mm radius, and apical curvature of 30° and 2-mm radius) artificial canals. The number of cycles to fracture was calculated. The bending resistance of both files were tested using a universal testing machine where the files were bent until reach 45°. Scanning electron microscopy and x-ray energy-dispersive spectrometric analysis were used for imaging the fractured segments, while the atomic force microscope was used to quantify the surface roughness average (Ra). RESULTS: EdgeEvolve files exhibited higher cyclic fatigue resistance than ProTaper Gold files in single- and double-curved canals (p 0.05). EdgeEvolve files showed significantly lower Ra values than ProTaper Gold files (p < 0.05). CONCLUSIONS: Within the limitation of this study, EdgeEvolve files exhibited significantly higher cyclic fatigue resistance than ProTaper Gold files in both single- and double-curved canals.


Subject(s)
Fatigue , Microscopy, Electron, Scanning , Pliability , Radius
20.
Restorative Dentistry & Endodontics ; : e2-2019.
Article in English | WPRIM | ID: wpr-741989

ABSTRACT

OBJECTIVES: The purpose of this research was to identify the top 10 most-cited articles on the management of fractured or broken instruments and to perform a bibliometric analysis thereof. MATERIALS AND METHODS: Published articles related to fractured instruments were screened from online databases, such as Web of Science, Scopus, PubMed, and ScienceDirect, and highly cited papers, with at least 50 citations since publication, were identified. The most-cited articles were selected and analysed with regard to publication title, authorship, the journal of publication, year, institution, country of origin, article type, and number of citations. RESULTS: The top 10 most-cited articles were from various journals. Most were published in the Journal of Endodontics, followed by the International Endodontic Journal, and Dental Traumatology. The leading countries were Australia, Israel, Switzerland, the USA, and Germany, and the leading institution was the University of Melbourne. The majority of articles among the top 10 articles were clinical research studies (n = 8), followed by a basic research article and a non-systematic review article. CONCLUSIONS: This bibliometric analysis revealed interesting information about scientific progress in endodontics regarding fractured instruments. Overall, clinical research studies and basic research articles published in high-impact endodontic journals had the highest citation rates.


Subject(s)
Australia , Authorship , Bibliometrics , Endodontics , Germany , Israel , Publications , Root Canal Preparation , Switzerland , Traumatology
SELECTION OF CITATIONS
SEARCH DETAIL